From Battery Recycling to Cell Reassembly: RockPlus MES Enables Production Management and Quality Traceability for Second-Life Lithium Batteries
Smart Manufacturing in Practice
With the rapid development of the new energy industry, lithium battery recycling and second-life applications are becoming increasingly important in manufacturing. Unlike new battery production, recycled batteries vary in their origins, operating histories, and remaining performance. Even cells recovered from the same battery pack may exhibit significant differences in capacity, voltage, internal resistance, and overall condition.
Accurately evaluating the quality of each battery cell and using inspection results to guide grading, grouping, and reuse have therefore become essential requirements for companies involved in battery recycling and remanufacturing.
XXX New Materials Technology Co., Ltd. specializes in the recovery, disassembly, repair, testing, and regrouping of lithium batteries for second-life applications. Previously, its production operations relied heavily on manual records and standalone cell grouping tools, with limited integration between receiving, disassembly, repair, testing, inventory, and cell matching processes.
To address these challenges, an MES management system was developed to connect the key stages of battery cell processing. Its work order management, barcode-based process control, quality verification, and traceability capabilities closely align with the digital manufacturing management approach of RockPlus MES.
Establishing Individual Cell Traceability from Battery Pack Receiving
When recycled battery packs arrive at a facility, they must first undergo receiving, registration, and disassembly. Since these batteries may originate from different production batches and usage environments, each recovered cell requires a new identification record before entering subsequent repair, testing, and regrouping processes.
The project combines PDA mobile terminals with workstation-based barcode scanning applications to manage battery pack receiving, cell registration, container binding, and repair process tracking.
Operators scan battery pack barcodes to complete receiving operations. After disassembly, individual cells are assigned new identification barcodes, with different prefixes distinguishing qualified and rejected cells. When cells are placed into storage containers, operators scan both the container barcode and the cell barcodes to establish their relationships.
These barcode associations allow the system to identify and track individual cells as they move between workstations, storage areas, and processing stages.
The item-level traceability approach emphasized by RockPlus MES is reflected in the use of a unique barcode throughout the cell's manufacturing journey. Rather than treating cells as anonymous materials stored in containers, the system maintains individual identities linked to inventory status, test results, and processing records.
For operations such as repair, container loading, and process transfers, the system records relevant operational details, including personnel, timestamps, and process history. This reduces dependence on paper-based records and makes it easier to investigate the manufacturing history of individual cells.
Automatically Integrating Test Data to Support Quality Decisions
Whether a recovered lithium battery cell can be reused depends largely on its actual performance.
During the remanufacturing process, cells must undergo capacity testing, resting and aging, open-circuit voltage (OCV) measurement, and internal resistance evaluation. These measurements help determine the remaining capacity, performance condition, and potential application of each cell.
However, capacity-testing equipment often operates through independent industrial control systems. When test results remain isolated in equipment databases, linking them to cell identification records, inventory information, and production work orders becomes difficult.
To resolve this issue, the project uses a background data synchronization service to connect with the Fangchi capacity-testing equipment environment.
The service periodically retrieves cell testing records and associates them with the corresponding cell barcodes, fixtures, test channels, and capacity results within the MES database. Information previously stored separately in equipment systems becomes available for subsequent cell grading, inventory queries, and grouping decisions.
This approach reflects an important aspect of RockPlus MES manufacturing execution management: production equipment generates actual process and quality data, while MES uses that information to manage product status, enforce process requirements, and support quality decisions.
By automatically synchronizing testing information, the system reduces repeated manual data entry and provides a more consistent data foundation for cell evaluation and manufacturing traceability.
Managing Two-Day and Seven-Day Aging with Inventory Visibility
After capacity testing, battery cells cannot immediately proceed to grouping. They must undergo defined resting periods and staged inspections to verify their electrical performance and stability.
Because cells enter the aging area at different times, manual inventory tracking can lead to premature removal, overdue testing, or inaccurate storage records.
To address these challenges, the project establishes inventory management processes for both two-day and seven-day aging stages.
Using PDA barcode scanning, operators associate cells with their fixtures, storage racks, and storage locations. The system records the time at which each cell enters storage and calculates the required testing schedule according to its current processing stage.
Once a cell has completed the required resting period, it can be released for the corresponding inspection. If an operator attempts to remove a cell before the specified time, the system blocks the operation. Exceptional early-release operations require appropriate authorization and are recorded for subsequent review.
The production area also uses electronic aging inventory dashboards to display the status of cells across different storage racks.
Color-coded indicators distinguish cells undergoing normal aging, those approaching their testing deadlines, those requiring immediate inspection, and fixtures that have already been removed from service.
This visual management approach allows supervisors to identify cells requiring attention without manually reviewing individual rack records.
Within the manufacturing execution principles of RockPlus MES, process control extends beyond recording completed operations. It also involves connecting testing schedules, inventory status, and user permissions so that manufacturing requirements can be enforced during actual material movements.
By linking time-based quality requirements with warehouse operations, the system helps improve control over aging and inspection activities.
Cell Grouping Requires More Than Matching Quantities
After capacity testing and aging inspections are completed, battery cells must be graded according to performance characteristics such as capacity, voltage, and internal resistance.
Only cells that satisfy the applicable requirements can be considered for regrouping into battery modules or packs.
The project introduces a dedicated cell matching and grouping workflow to manage this process.
Engineers configure grouping conditions according to production work orders. These conditions include the acceptable performance range for individual cells and the permitted differences between cells within the same group.
When operators scan a cell barcode, the system retrieves the corresponding test history and evaluates whether the cell meets the defined grouping requirements.
Cells that fail the verification are identified with the relevant rejection reasons, allowing production personnel to investigate or adjust the selection. Qualified cells enter the candidate pool, where grouping algorithms calculate suitable combinations according to the configured criteria.
During the actual grouping operation, the system also verifies scanned cells against the production work order, module identification number, and predefined grouping list.
If an operator scans a cell that does not belong to the current group, the application displays a prominent warning to prevent the incorrect cell from being included in the battery assembly.
After grouping is completed, the corresponding records proceed to inspection and statistical review. The system maintains information about grouping results, rejected cells, and cells that have not yet been successfully grouped.
This workflow closely relates to the work order execution, quality verification, and process error-proofing capabilities associated with RockPlus MES.
By converting inspection measurements into actionable grouping conditions, the system helps engineers and operators make decisions based on actual cell performance rather than relying entirely on manual judgment.
It also reduces the risk of assembling groups containing cells with incompatible performance characteristics.
Connecting Production, Inventory, and Quality Data for Traceability
Lithium battery recycling and second-life manufacturing involve multiple production stages, storage locations, and types of shop-floor terminals.
In addition to monitoring production output, supervisors need to understand where individual cells are stored, which inspections have been completed, whether any quality abnormalities have occurred, and which work orders remain unfinished.
The project establishes a management environment combining a web-based administration platform, Windows workstation applications, PDA mobile terminals, and electronic production dashboards.
Through integrated data interfaces, the system manages production work orders, cell inventory, test records, process histories, and operational logs.
Production and quality personnel can search for a particular cell using its barcode to retrieve inventory information and performance measurements. They can also review process records to understand how the cell has moved through receiving, disassembly, repair, capacity testing, aging, grading, and grouping.
Management reports provide visibility into workstation production output, individual cell processing volumes, and battery pack production performance.
For defective or scrapped cells, the system maintains the corresponding rejection reasons and handling records, supporting subsequent investigation and quality analysis.
In a manufacturing execution environment aligned with RockPlus MES, the relationships between work orders, barcodes, workstations, and test data are especially important.
For example, when investigating a cell that has already been incorporated into a battery module, personnel need to trace its original identification, capacity test results, aging history, grading criteria, and grouping records.
By maintaining these relationships within a connected data environment, the system reduces the need to search separate equipment databases, paper records, and manually prepared spreadsheets.
As cells move through successive manufacturing stages, their production and quality records continue to accumulate. This provides operators with the information needed to make process decisions based on actual test results and gives quality teams a more complete foundation for investigating manufacturing abnormalities.
More Case Studies